Johnson Controls VG7441RT+823C00 Brass Globe Valve with Pneumatic Actuator 1.5" NC 3-7 PSI
Johnson Controls VG7251NT+3008B 1" Globe Valve with Pneumatic Actuator 11.6 Cv 3-6 PSI
Resideo by Honeywell AP5210-30 Airflow Differential Pressure Switch 0.30-12.0 WC
Siemens 599-05982 4-Inch Normally Open Bronze Valve Assembly with Modulating Actuator
Siemens 331-916 AP331 Side Mounting Bracket for #3 and #4 Pneumatic Damper Actuators
Siemens Building Technology 599-02002 1/2" NPT Brass Normally Closed HVAC Control Valve
Siemens 540-680FB Room Temperature Sensor with Setpoint Adjustment, Fahrenheit Scale, White
Siemens Building Technology 426855108 Manual Crank Assembly for SKB/SKC Actuators
Johnson Controls VG7842NT+74CHGC 1" 3-Way Proportional Globe Valve 11.6 Cv 24V Spring Return
Siemens Building Technology 599-03129 Flowrite 1/2" 2-Way Control Valve Normally Closed 4.0 Cv
Siemens Building Technology 599-02070 3/4" 3-Way Mixing Globe Valve 6.3 Cv Brass Trim
Siemens Building Technology 599-02047 1/2" Stainless Steel 2-Way Normally Open Valve
Asco HT8262H78 High-Temperature Solenoid Valve 1/4" NPT Normally Closed 0-50 PSI
Schneider Electric VBB2N00 1/2" NPT 2-Way Brass Characterized Ball Valve Body 0.3 Cv
Schneider Electric VB-7263-0-4-5 Venta 2-Way Globe Valve Body 3/4" NPT 5.5 Cv Steam
Schneider Electric VA-7223-804-4-08 1" 2-Way Globe Valve Assembly Normally Closed 24V
Schneider Electric MA51-7103-100 SmartX Linear Valve Actuator 24V Spring Return Two-Position 105 lb
Schneider Electric VK4-7313-303-4-4 3-Way Mixing Globe Valve 1/2" NPT Bronze 4.4 CV with Positioner
Schneider Electric VK4-7313-303-4-2 3-Way Mixing Valve 1/2 Inch NPT 2.2 Cv with Positioner
Schneider Electric VK4-7313-303-4-11 2" NPT 3-Way Mixing Globe Valve Assembly with Positioner 41 Cv
Schneider Electric VK4-7313-303-4-10 1.5" 3-Way Mixing Globe Valve Assembly with Positioner
Schneider Electric VK4-7313-302-4-8 1 Inch 3-Way Pneumatic Mixing Valve with Positioner 14 CV Bronze
Square D 9013GHG2J25 Pumptrol Pressure Switch DPST 40-200 PSI NEMA 1 Air Compressor Water Pump
Schneider Electric VK4-8213-602-5-14 4" Two-Way Globe Valve Assembly with Pneumatic Actuator and Positioner
Schneider Electric VK4-7313-303-4-9 1-1/4 Inch NPT Mixing Valve with Positioner 20Cv
Schneider Electric VK4-7313-303-4-8 1" 3-Way Mixing Globe Valve with Positioner
Schneider Electric VK4-7313-302-4-4 1/2" 3-Way Mixing Globe Valve Assembly with Pneumatic Actuator
Schneider Electric VK4-7313-302-4-2 1/2" Mixing Valve 5-10 PSI 2.2 Cv with Positioner
Schneider Electric VK4-7313-302-4-11 2" 3-Way Mixing Globe Valve Assembly with Positive Positioner
Schneider Electric VK4-7313-302-4-10 3-Way Mixing Globe Valve with Pneumatic Actuator and Positioner
Schneider Electric VK4-7223-303-4-8 1" Pneumatic Globe Valve Assembly N/C 2-Way
Schneider Electric VK4-7223-303-4-6 3/4" Normally Closed Spring Return Valve Actuator
Schneider Electric VK4-7223-303-4-11 2-Inch Pneumatic Control Valve Normally Closed
Why Thermostats, Controls & Valves Are Essential to Your Vehicle
Few systems in your vehicle are as quietly important as the network of thermostats, controls, and valves that govern engine temperature. Acting as the gatekeeper for your car's cooling system, these components make split-second decisions about coolant flow that can mean the difference between optimal performance and catastrophic engine failure. Understanding what they do — and why they matter — is the first step to keeping your vehicle running reliably for years to come.
How Engine Thermostats Work
A thermostat is a key component of the engine's cooling system that regulates coolant flow based on engine temperature. It remains closed when the engine is cold, allowing it to warm up quickly, and opens as the engine reaches optimal operating temperature to let coolant circulate to the radiator. This seemingly simple action has profound effects on engine health and efficiency.
During normal use, the thermostat is never in the fully closed or fully open position — it depends on the condition of the engine and gradually nears either state to control coolant flow. Most thermostats open at 180–195°F and use a wax-filled mechanism that expands with heat to operate. This purely mechanical response is remarkably reliable, though modern vehicles increasingly use electronically controlled variants for even greater precision.
The Broader Category: Controls & Valves
The thermostat is just one piece of a larger puzzle. The Thermostats, Controls & Valves category encompasses a wide range of components that regulate fluid flow, temperature, and pressure throughout your vehicle's systems. These include:
- Coolant control valves — designed to control the distribution and flow of coolant, managing heat transfer between the engine, radiator, and heater core.
- Bypass thermostats — direct coolant flow through a bypass when the engine is cold and redirect it to the radiator once warmed up.
- Electronic and map-controlled thermostats — used in advanced cooling systems to maintain optimized cooling based on changing driving conditions, offering a significant improvement in accuracy over purely mechanical types.
- Temperature sensors and switches — monitoring components that feed data to the engine control unit, enabling intelligent management of cooling and heating circuits.
- Heater control valves — regulate how much hot coolant flows into the cabin heater core, directly affecting interior comfort and defrost performance.
Why These Parts Matter for Performance and Longevity
Maintaining proper engine temperature improves fuel efficiency, reduces engine wear caused by temperature fluctuations, and supports emission control by ensuring consistent combustion temperature. Conversely, common failure modes include a thermostat getting stuck open — causing poor heating — or stuck closed, which causes overheating. Either condition places unnecessary stress on the entire cooling system and can lead to costly repairs.
The main engine coolant is often used to cool one or more additional heat exchangers or radiators, such as a transmission oil cooler, a fuel cooler, or an air-charge cooler, making this category relevant well beyond just the primary engine cooling circuit.
What to Consider When Shopping This Category
When selecting a thermostat, control, or valve, always match the component's temperature rating to your vehicle manufacturer's specification. Thermostats are designed to meet manufacturer's specifications for temperature ratings, which is critical for optimal engine performance. Also consider whether your application calls for a conventional mechanical unit or a more advanced electronically controlled design, especially in late-model vehicles with precision thermal management systems. Finally, plan to replace your thermostat every 100,000 miles or when you notice temperature regulation problems to stay ahead of potential failures.